Smoke and CO alarm rules for landlords in England

Barry McGee, landlord and founder of LetbookLast updated 28 Oct 2026

Landlords in England must fit a smoke alarm on every storey with living accommodation and a carbon monoxide alarm in any such room with a fixed combustion appliance, other than a gas cooker. They must check each alarm works on the day a new tenancy begins. This page covers England only.

  • England: Smoke and carbon monoxide alarms in England

Which rooms need an alarm

Regulation 4 of the Smoke and Carbon Monoxide Alarm (England) Regulations 2015, as amended, sets the duties during occupation:

  • a smoke alarm on each storey that has a room used wholly or partly as living accommodation (a hall or landing counts as a room);
  • a carbon monoxide alarm in any such room that contains a fixed combustion appliance, other than a gas cooker.

A bathroom or lavatory counts as living accommodation. Source: regulation 4, legislation.gov.uk.

Gov.uk summarises this for landlords as providing a smoke alarm on each storey, and a carbon monoxide alarm in any room with a solid fuel burning appliance such as a coal fire or wood burning stove. The regulation text above is wider, so follow the regulation. Source: GOV.UK, your landlord's safety responsibilities (opens in a new tab).

Testing on day one

For a new tenancy, you or someone acting for you must check that each required alarm is working on the day the tenancy begins. A tenancy begins when the tenant becomes entitled to possession under its terms. A "new tenancy" is one granted on or after 1 October 2022, subject to the exclusions in the regulation. Source: regulation 4.

Repairs once a fault is reported

If a tenant, or their nominated representative, reports that an alarm is faulty, and it is found not to work, you must repair or replace it. Deciding whether the alarm is working, and any repair or replacement, must be done by or on behalf of the landlord as soon as reasonably practicable. Source: regulation 4.

Penalty

If the local housing authority has reasonable grounds to believe you are in breach, it must serve a remedial notice, which requires the action "within 28 days beginning with the day on which the notice is served" (regulation 5). If you then do not take that action, and cannot show you took all reasonable steps, the authority may require you to pay a penalty charge. The amount "must not exceed £5,000". Source: regulation 8, legislation.gov.uk and regulation 6.

Summary

WhatRuleSource
Smoke alarmEach storey with living accommodationReg 4
CO alarmRooms with a fixed combustion appliance, not a gas cookerReg 4
CheckOn the day a new tenancy beginsReg 4
Faulty alarm reportedRepair or replace as soon as reasonably practicableReg 4
Penalty chargeUp to £5,000, after a remedial notice is not complied withReg 8

Track the checks with Letbook

The law requires the check at the start of each tenancy. It does not set a yearly interval, though many landlords test regularly. Letbook is a compliance tracker for landlords: it holds a smoke and CO alarm check item for each property in England and emails you before the date you set lapses. Sign up free.

Related guides: smoke, heat and CO alarms in Scotland, gas safety certificate rules and EICR rules.

Wales and Northern Ireland: smoke and CO alarm rules.

Sources

  • Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulation 4, legislation.gov.uk
  • Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulation 8, legislation.gov.uk
  • Private renting: your landlord's safety responsibilities, GOV.UK

Facts checked on 28 October 2026. This page is general information, not legal advice.