Smoke, heat and CO alarms for landlords in Scotland
Barry McGee, landlord and founder of LetbookLast updated 5 Nov 2026
In Scotland, a private landlord must provide interlinked smoke alarms in the living room and every hallway and landing, a heat alarm in the kitchen, and a carbon monoxide detector wherever there is a fixed carbon-fuelled appliance or a flue. These rules have applied to every home in Scotland since 1 February 2022, as part of the tolerable standard. This page covers Scotland only; England, Wales and Northern Ireland have their own rules.
Scotland: Smoke, heat and CO alarms in Scotland
Where the rule comes from
- The tolerable standard. Section 86(1) of the Housing (Scotland) Act 1987 (opens in a new tab) says a house must have "satisfactory equipment installed for detecting, and for giving warning of, fire or suspected fire" and the same for carbon monoxide "in a concentration that is hazardous to health".
- The date. Those two paragraphs, (j) and (k), were inserted by SSI 2019/8. Its start date was moved from 1 February 2021 to 1 February 2022 by SSI 2021/46.
- Moved out of the repairing standard. Before then, fire and CO warning were limbs (f) and (g) of the repairing standard in section 13 of the Housing (Scotland) Act 2006. They were omitted on 1 February 2022. The Scottish Government's repairing standard guidance for private landlords (opens in a new tab) says the requirement "is now part of the Tolerable Standard and is therefore required in all tenures, including private rented housing."
- Guidance counts. Section 86(1A) says "regard shall be had to any guidance issued by the Scottish Ministers". That guidance is Satisfactory fire and carbon monoxide detection: tolerable standard guidance (opens in a new tab), and the detail below comes from it.
Smoke and heat alarms
Paragraph 16.5 of the guidance asks for:
- one smoke alarm in the room most used for daytime living, normally the living room;
- one smoke alarm in every circulation space on each storey, such as hallways and landings;
- one heat alarm in every kitchen;
- all smoke and heat alarms ceiling mounted and interlinked.
An open-plan kitchen and living room needs only one alarm, if it can sit no more than 7.5 metres from any point in the room. A landing or hall alarm should be no more than 3 metres from the main bedroom door.
Mains or battery. Paragraph 16.6 permits mains-operated alarms with battery backup, and "tamper proof long-life lithium battery alarms (i.e. not PP3 type or user-replaceable)". The guidance does not require mains wiring.
An existing kitchen smoke alarm need not be swapped for a heat alarm until it reaches the end of its manufacturer's recommended lifespan.
Carbon monoxide detectors
- Where. Paragraph 17.5: in all rooms "where there is a fixed combustion appliance (excluding an appliance used solely for cooking) or a flue". That includes boilers, open fires, heaters and stoves that burn a carbon-based fuel.
- Not for cookers. The guidance says "A carbon monoxide detector is not required for a gas cooker or hob."
- Not needed in a cellar, attic or garage that is not used as living accommodation.
- Siting. Between 1 and 3 metres from the appliance, and not in a cupboard. Ceiling mounted at least 300 mm from a wall, or wall mounted at least 150 mm below the ceiling and above any door or window.
- Power. A battery designed to last the detector's working life, with a warning when that life is due to end, or a hard-wired mains detector to BS EN 50291 (Type A), not a plug-in.
- No interlink needed. CO detectors do not have to be interlinked with each other or with the fire alarms.
At a glance
| Item | Where | Power and notes |
|---|---|---|
| Smoke alarm | Living room, and every hallway and landing | Mains with backup, or sealed long-life battery |
| Heat alarm | Every kitchen | Mains with backup, or sealed long-life battery |
| Interlink | All smoke and heat alarms together | Not needed for CO detectors |
| CO detector | Rooms with a fixed carbon-fuelled appliance or flue, not cookers | Battery for its working life, or hard-wired mains |
Source: tolerable standard guidance, chapters 16 and 17, gov.scot (opens in a new tab).
Who pays and what a tenant can do
The Scottish Government is plain about cost: "Installing fire alarms and carbon monoxide detectors and paying for them is the responsibility of the homeowner or landlord" (gov.scot, fire and smoke alarms: the law (opens in a new tab)).
A private tenant whose home fails the tolerable standard can apply to the First-tier Tribunal for Scotland (Housing and Property Chamber), says paragraph A.1 of the repairing standard guidance (opens in a new tab). mygov.scot (opens in a new tab) adds that a landlord must also fit specialist alarms for a deaf or hard of hearing tenant.
Testing and replacing
The guidance says alarms "should be regularly maintained and tested in accordance with manufacturer's instructions". It sets no fixed yearly test. mygov.scot (opens in a new tab) says mains-wired alarms should be fitted by a qualified electrician and replaced every 10 years.
A simple routine:
- Walk the home with the table above at each change of tenant and note each alarm's location and expiry date.
- Press the test button on every alarm and check the interlink sets off the others.
- Replace any alarm past its manufacturer's lifespan, or any CO detector giving its end-of-life warning.
- Keep a dated note or photo of the check.
Track the check with Letbook
Letbook is a compliance tracker for private landlords. For each property in Scotland it adds a "Smoke, heat and CO alarm check" item and emails you before the date lapses. The yearly reminder is Letbook's default, not a legal interval. Sign up free.
Related guides: smoke and CO alarm rules in England, landlord repair duties by nation, gas safety in Scotland, Wales and Northern Ireland and notice to leave in Scotland.
Wales and Northern Ireland: smoke and CO alarm rules.
Sources
- Housing (Scotland) Act 1987, section 86, legislation.gov.uk
- Tolerable Standard (Extension of Criteria) Order 2019, SSI 2019/8, article 2, legislation.gov.uk
- Tolerable Standard (Extension of Criteria) Amendment Order 2021, SSI 2021/46, article 2, legislation.gov.uk
- Housing (Scotland) Act 2006, section 13, legislation.gov.uk
- Satisfactory fire and carbon monoxide detection: tolerable standard guidance, gov.scot (opens in a new tab)
- Repairing Standard: statutory guidance for private landlords, Annex A, gov.scot (opens in a new tab)
- Fire and smoke alarms: the law, gov.scot (opens in a new tab)
- Getting repairs done as a private tenant, mygov.scot (opens in a new tab)
- Fire safety if you own your home, mygov.scot (opens in a new tab)
Facts checked on 5 November 2026, relying on the 1 February 2022 commencement of section 86(1)(j) and (k) under SSI 2019/8 as amended by SSI 2021/46. This page is general information, not legal advice.