Skip to main content

Smoke and CO alarms: Wales and Northern Ireland

Barry McGee, landlord and founder of LetbookLast updated 12 Nov 2026

In Wales a landlord must fit a linked smoke alarm on each storey and a carbon monoxide alarm in each room with a gas, oil-fired or solid fuel appliance. In Northern Ireland, since 2024, a landlord must also fit interlinked smoke alarms, a heat alarm in every kitchen and a CO alarm where there is a fixed combustion appliance or flue. England and Scotland have their own rules: see England and Scotland.

  • Wales: Smoke and carbon monoxide alarms in Wales
  • Northern Ireland: Smoke and carbon monoxide alarms in Northern Ireland

Wales

The rule is regulation 5 of the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022 (opens in a new tab), in force from 1 December 2022. It says: "The landlord must ensure that, during each period of occupation, on each storey of the dwelling there is a smoke alarm which is" in repair and proper working order, connected to the dwelling's electrical supply, and linked to every other smoke alarm connected to that supply.

A carbon monoxide alarm in working order must be "in each room of the dwelling which contains a gas appliance, an oil-fired combustion appliance or a solid fuel burning combustion appliance".

A dwelling without the alarms is treated as unfit for human habitation until they are fitted. The explanatory note says the rules apply to secure contracts, periodic standard contracts and fixed-term standard contracts under 7 years. The regulation sets no test interval and no fine.

Northern Ireland

The rules are in the Smoke, Heat and Carbon Monoxide Alarms for Private Tenancies Regulations (Northern Ireland) 2024. They applied to new tenancies from 1 September 2024 and to other private tenancies from 1 December 2024 (regulation 1).

Regulation 3 requires:

  • a smoke alarm in the room most used for daytime living and in every circulation space on each storey;
  • a heat alarm in every kitchen;
  • a CO alarm in any room or circulation space with a fixed combustion appliance or a flue.

The landlord must ensure each alarm is "in proper working order at the beginning of every new tenancy", replaced when notified it is faulty, and replaced before the manufacturer's expiry date. Regulation 4 says smoke and heat alarms must be interlinked, and hard wired or battery sealed. A fixed combustion appliance includes boilers, fires, heaters and stoves fuelled by solid fuel, oil or gas, but not a gas cooker or oven (regulation 2).

Failing the duty is an offence under Article 11B of the Private Tenancies (Northern Ireland) Order 2006. The Article itself sets no fine.

Summary

WalesNorthern Ireland
Smoke alarmsEach storey, mains connected, linkedDaytime living room and each storey's circulation space, interlinked
Heat alarmNot required by the regulationEvery kitchen
CO alarmRooms with gas, oil or solid fuel applianceRooms or circulation space with a fixed combustion appliance or flue
CheckedDuring each period of occupationWorking at the start of every new tenancy

Track the checks with Letbook

Letbook is a compliance tracker for landlords. It holds a safety check item for each property, with a date you set, and emails you before it lapses. Sign up free.

Related guides: Wales occupation contracts, Northern Ireland private tenancies and gas safety in Scotland, Wales and Northern Ireland.

Sources

  • Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022, regulation 5, legislation.gov.uk
  • Explanatory note to the 2022 Regulations, legislation.gov.uk
  • Smoke, Heat and Carbon Monoxide Alarms for Private Tenancies Regulations (Northern Ireland) 2024, legislation.gov.uk
  • Private Tenancies (Northern Ireland) Order 2006, Article 11B, legislation.gov.uk