Smoke and CO alarms: Wales and Northern Ireland
Barry McGee, landlord and founder of LetbookLast updated 12 Nov 2026
In Wales a landlord must fit a linked smoke alarm on each storey and a carbon monoxide alarm in each room with a gas, oil-fired or solid fuel appliance. In Northern Ireland, since 2024, a landlord must also fit interlinked smoke alarms, a heat alarm in every kitchen and a CO alarm where there is a fixed combustion appliance or flue. England and Scotland have their own rules: see England and Scotland.
Wales: Smoke and carbon monoxide alarms in Wales Northern Ireland: Smoke and carbon monoxide alarms in Northern Ireland
Wales
The rule is regulation 5 of the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022 (opens in a new tab), in force from 1 December 2022. It says: "The landlord must ensure that, during each period of occupation, on each storey of the dwelling there is a smoke alarm which is" in repair and proper working order, connected to the dwelling's electrical supply, and linked to every other smoke alarm connected to that supply.
A carbon monoxide alarm in working order must be "in each room of the dwelling which contains a gas appliance, an oil-fired combustion appliance or a solid fuel burning combustion appliance".
A dwelling without the alarms is treated as unfit for human habitation until they are fitted. The explanatory note says the rules apply to secure contracts, periodic standard contracts and fixed-term standard contracts under 7 years. The regulation sets no test interval and no fine.
Northern Ireland
The rules are in the Smoke, Heat and Carbon Monoxide Alarms for Private Tenancies Regulations (Northern Ireland) 2024. They applied to new tenancies from 1 September 2024 and to other private tenancies from 1 December 2024 (regulation 1).
Regulation 3 requires:
- a smoke alarm in the room most used for daytime living and in every circulation space on each storey;
- a heat alarm in every kitchen;
- a CO alarm in any room or circulation space with a fixed combustion appliance or a flue.
The landlord must ensure each alarm is "in proper working order at the beginning of every new tenancy", replaced when notified it is faulty, and replaced before the manufacturer's expiry date. Regulation 4 says smoke and heat alarms must be interlinked, and hard wired or battery sealed. A fixed combustion appliance includes boilers, fires, heaters and stoves fuelled by solid fuel, oil or gas, but not a gas cooker or oven (regulation 2).
Failing the duty is an offence under Article 11B of the Private Tenancies (Northern Ireland) Order 2006. The Article itself sets no fine.
Summary
| Wales | Northern Ireland | |
|---|---|---|
| Smoke alarms | Each storey, mains connected, linked | Daytime living room and each storey's circulation space, interlinked |
| Heat alarm | Not required by the regulation | Every kitchen |
| CO alarm | Rooms with gas, oil or solid fuel appliance | Rooms or circulation space with a fixed combustion appliance or flue |
| Checked | During each period of occupation | Working at the start of every new tenancy |
Track the checks with Letbook
Letbook is a compliance tracker for landlords. It holds a safety check item for each property, with a date you set, and emails you before it lapses. Sign up free.
Related guides: Wales occupation contracts, Northern Ireland private tenancies and gas safety in Scotland, Wales and Northern Ireland.
Sources
- Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022, regulation 5, legislation.gov.uk
- Explanatory note to the 2022 Regulations, legislation.gov.uk
- Smoke, Heat and Carbon Monoxide Alarms for Private Tenancies Regulations (Northern Ireland) 2024, legislation.gov.uk
- Private Tenancies (Northern Ireland) Order 2006, Article 11B, legislation.gov.uk
Facts checked on 12 November 2026. This page is general information, not legal advice.